Transformer Calculations Question & Answers November 9, 2026 By Wat Electrical Transformers sit quietly at almost every point of the power system, from the generating station to the pole-mounted unit outside your home. They have no moving parts and rarely draw attention, yet nearly every unit of electrical energy you use has passed through several of them. A single transformer also holds a set of design trade-offs in its losses, its voltage drop under load, and the way it shares current with its neighbours. That is why transformer calculations are a core skill for electrical engineering students and for anyone preparing for GATE, ESE, or utility recruitment exams. The theory is short. The difficulty is in applying it under time pressure: choosing the right formula, referring values to the correct side, and keeping track of power factor and load fraction. Reading the equations once does not build that skill. Solving varied problems does. This article is a practice set of 100 multiple-choice questions built around four themes: Losses: what iron and copper losses depend on, and how the open-circuit and short-circuit tests reveal them. Efficiency: full-load, part-load, maximum, and all-day efficiency. Voltage regulation: the effect of load power factor, per-unit values, and short-circuit current. Parallel operation: load sharing, circulating currents, and which transformers can be connected. A short opening set covers basic ratios and EMF, and a closing set covers mixed topics such as short-circuit level, per-unit conversion, and autotransformers. How to use this bank Attempt each question before reading the hint. Each question has four options, a hint (the idea or formula to use), and the answer with a short working. Unless stated otherwise, the transformers are single-phase, the frequency is 50 Hz, and the load is at rated voltage. Voltage regulation is defined here relative to the no-load secondary voltage V20. This is the convention behind the approximate formula used in Section D. Some texts divide by the loaded voltage V2 instead, which gives slightly larger values (see Q54). Per-unit conversions between kVA bases assume an unchanged voltage base unless stated. Assume the paralleled transformers have the same X/R ratio, so their load currents are in phase and add arithmetically. Key Formulas Topic Formula EMF equation E = 4.44 f Φm N Turns ratio K = N2/N1 = V2/V1 = I1/I2 Referred resistance (to secondary) R02 = R2 + K² R1 Referred reactance (to secondary) X02 = X2 + K² X1 Iron loss Pi = Ph + Pe, with Ph ∝ f B^1.6 and Pe ∝ f² B² t² Copper loss at load fraction x Pcu = x² × Pcu(fl) Efficiency η = x S cosφ / (x S cosφ + Pi + x² Pcu(fl)) Load for maximum efficiency x = √(Pi / Pcu(fl)) Voltage regulation (defined on no-load voltage) %VR = (V20 − V2)/V20 × 100 Voltage regulation (alternative, on loaded voltage) %VR = (V20 − V2)/V2 × 100 Voltage regulation (approx.) ε = ε_r cosφ ± ε_x sinφ (+ lagging, − leading) Max regulation ε = ε_z, at cosφ = ε_r/ε_z (lagging) Zero regulation (leading) tanφ = ε_r/ε_x Load sharing in parallel Sa : Sb = (Sa,rated / Za%) : (Sb,rated / Zb%) Circulating current Ic = ΔE / (Z1 + Z2) Per-unit base change Z_pu,new = Z_pu,old × (S_base,new / S_base,old) × (V_base,old / V_base,new)² Q1). A single-phase transformer is rated 2200/220 V. If the primary has 1000 turns, the number of secondary turns is: 10 50 100 1000 None Hint Q2). The peak flux in a core is 0.02 Wb and the winding has 200 turns at 50 Hz. The induced RMS EMF is approximately: 888 V 444 V 1776 V 2220 V None Hint Q3). A 50 kVA, 2400/240 V single-phase transformer has a rated primary current of: 10.4 A 50 A 208.3 A 20.83 A None Hint Q4). For the same transformer (50 kVA, 2400/240 V), the rated secondary current is: 20.83 A 208.3 A 104.2 A 500 A None Hint Q5). A 3-phase, delta/star transformer is rated 11 kV/400 V (line values). The per-phase turns ratio N1/N2 is about: 27.5 47.6 28.6 82.5 None Hint Q6). An ideal transformer is rated 4400/220 V and the secondary supplies 100 A. The primary current is: 2 A 10 A 20 A 5 A None Hint Q7). A 10 Ω load is connected across the secondary of an ideal 20:1 step-down transformer (N1:N2 = 20:1). The load as seen from the primary is: 4000 Ω 200 Ω 0.5 Ω 20 Ω None Hint Q8). The HV line current of a 3-phase, 100 kVA, 11 kV/400 V transformer is: 2.62 A 9.09 A 5.25 A 3.03 A None Hint Q9). A transformer is operated at the same voltage but the frequency falls from 50 Hz to 40 Hz. The core flux: decreases by 20% decreases by 25% stays the same increases by 25% None Hint Q10). A transformer has R1 = 2 Ω, R2 = 0.02 Ω and K = N2/N1 = 0.1. The equivalent resistance referred to the secondary is: 0.022 Ω 0.22 Ω 0.04 Ω 2.02 Ω None Hint Q11). The iron loss of a transformer remains practically constant when: The load current is constant The supply voltage and frequency are constant The power factor is constant The temperature is constant None Hint Q12). The full-load copper loss of a transformer is 2000 W. At half load, the copper loss is: 500 W 1000 W 250 W 707 W None Hint Q13). The thickness of the core laminations is halved. The eddy current loss becomes: one-fourth half double unchanged None Hint Q14). The hysteresis loss at 50 Hz is 400 W. At 60 Hz with the same maximum flux density it is: 333 W 480 W 400 W 576 W None Hint Q15). A transformer has an iron loss of 1000 W at 50 Hz (hysteresis 600 W, eddy 400 W). At 60 Hz with the same flux density, the iron loss is: 1000 W 1200 W 1296 W 1440 W None Hint Q16). If the supply voltage rises by 10% at constant frequency, the iron loss rises by about: 10% 33% 1% 21% None Hint Q17). The open-circuit (no-load) test on a transformer is used to find: full-load copper loss and impedance voltage regulation at full load core loss and no-load parameters temperature rise under load None Hint Q18). The short-circuit test is done at a reduced voltage because: saturation of the core is needed for the test the transformer has no leakage impedance the test is quicker at low voltage rated current flows at only 5–10% of rated voltage None Hint Q19). The no-load power factor is: 0.227 0.1 0.45 0.9 None Hint Q20)The magnetising current Im is about: 0.45 A 1.95 A 2.0 A 0.23 A None Hint Q21). The core-loss resistance R0 (LV side) is: 110 Ω 220 Ω 113 Ω 484 Ω None Hint Q22). The equivalent impedance Z01 referred to the HV side is: 8 Ω 16 Ω 13.86 Ω 40 Ω None Hint Q23). The equivalent resistance R01 is: 16 Ω 40 Ω 8 Ω 4 Ω None Hint Q24). The equivalent reactance X01 is: 13.86 Ω 8 Ω 16 Ω 24 Ω None Hint Q25). A transformer has a full-load copper loss of 1200 W. At 80% load, the copper loss is: 800 W 768 W 640 W 960 W None Hint Transformer Calculations MCQs for Exams Q26). A transformer has an iron loss of 800 W and a full-load copper loss of 1600 W. The load fraction at which copper loss equals iron loss is: 0.707 0.5 0.8 1.0 None Hint Q27). Cold-rolled grain-oriented (CRGO) silicon steel is used for transformer cores mainly to reduce: copper loss leakage flux voltage regulation hysteresis loss None Hint Q28). Stray load loss in a transformer is caused mainly by: saturation of the core limbs dielectric breakdown in the oil eddy currents from leakage flux in the tank and clamps mechanical friction in the cooling fans None Hint Q29). The full-load efficiency at 0.8 power factor lagging is: 96.97% 95.2% 97.5% 98.1% None Hint Q30). The efficiency at half load, 0.8 pf, is: 97.2% 95.0% 96.68% 98.0% None Hint Q31). The load (as a fraction of full load) at maximum efficiency is: 0.667 0.8165 0.9 1.22 None Hint Q32). The kVA load at maximum efficiency is: 66.7 kVA 75 kVA 100 kVA 81.65 kVA None Hint Q33). The maximum efficiency at 0.8 pf is about: 96.5% 97.9% 98.5% 97.03% None Hint Q34). For a given power factor, the efficiency of a transformer is maximum when: Pi = 2 Pcu Pi = Pcu Pcu = 2 Pi Pi = 0 None Hint Q35). At a given load current, the efficiency of a transformer is highest at: unity pf 0.5 pf lagging 0.8 pf leading zero pf None Hint Q36). The full-load efficiency is: 96.2% 98.0% 97.47% 98.5% None Hint Q37). The load at maximum efficiency is: 31.6 kVA 45 kVA 39.53 kVA 50 kVA None Hint Q38). The maximum efficiency is: 97.0% 98.2% 98.9% 97.53% None Hint Q39). All-day (energy) efficiency is defined as: The average of the full-load and half-load efficiencies The energy output over 24 h divided by the energy input over 24 h The power output at full load divided by the power input The highest efficiency reached at any load None Hint Q40). A 10 kVA distribution transformer has a core loss of 100 W and a full-load copper loss of 150 W. It runs 8 h at full load, unity pf, and 16 h at no load. The all-day efficiency is: 95.69% 93.2% 97.1% 98.0% None Hint Q41). Distribution transformers are designed with a low iron loss relative to copper loss because: They are always loaded to full capacity They are energised all day but loaded only part of the time Copper is cheaper than core steel They operate at a high frequency None Hint Q42). A transformer delivers 49 kW and has an efficiency of 98%. Its total losses are: 0.5 kW 2.0 kW 1.0 kW 2.45 kW None Hint Q43). A 20 kVA transformer has Pi = 300 W and Pcu(fl) = 400 W. At 75% load and unity pf, the efficiency is: 95.9% 97.4% 98.1% 96.62% None Hint Q44). A 100 kVA transformer has Pi = 0.8 kW and Pcu(fl) = 1.2 kW. At 25% load and 0.9 pf, the efficiency is: 96.26% 94.5% 97.8% 98.4% None Hint Q45). A transformer has maximum efficiency at 60% of full load and an iron loss of 1.2 kW. Its full-load copper loss is: 3.33 kW 0.72 kW 2.0 kW 5.0 kW None Hint Q46). A transformer has a full-load copper loss of 2 kW and reaches maximum efficiency at 50% of full load. Its iron loss is: 0.25 kW 1.0 kW 2.0 kW 0.5 kW None Hint Q47). The efficiency at full load, 0.8 pf, is: 93.5% 96.0% 94.79% 97.2% None Hint Q48). The fraction of full load at maximum efficiency is: 0.75 0.9129 0.8165 1.095 None Hint Q49). Transformers are rated in kVA rather than kW because: kW cannot be measured on a transformer The power factor is always unity Efficiency is always 100% Losses depend on voltage and current, not on power factor None Hint Q50). A transformer reaches a maximum efficiency of 98.5% at unity pf when delivering 80 kVA. Its iron loss is about: 0.609 kW 1.218 kW 1.5 kW 0.3 kW None Hint Transformer Calculations MCQs for Interviews Q51). A 25 kVA transformer has Pi = 250 W and Pcu(fl) = 400 W. At 60% load and 0.8 pf, the efficiency is: 95.4% 96.82% 97.6% 94.9% None Hint Q52). A 200 kVA transformer has Pi = 1.0 kW and Pcu(fl) = 2.0 kW. Its maximum efficiency at 0.9 pf is: 97.5% 98.9% 98.45% 96.9% None Hint Q53). The voltage regulation of a transformer, referred to the no-load voltage (the convention used in this bank), is defined as: (V2 − V20)/V2 × 100 V2/V20 (V20 − V2)/V20 × 100 V20/V2 None Hint Q54). The no-load secondary voltage is 240 V and the full-load secondary voltage is 230 V. Taking regulation as the voltage fall as a percentage of the no-load voltage, the regulation is: 2.5% 4.35% 10% 4.17% None Hint Q55). The regulation at full load, 0.8 pf lagging, is: 3.6% 2.4% 4.0% 5.5% None Hint Q56). The regulation at full load, unity pf, is: 4% 1.5% 5.5% 0 None Hint Q57). The regulation at full load, 0.8 pf leading, is +1.2% −1.2% −3.6% 0 None Hint Q58). The load power factor at which the regulation is maximum is: 0.351 leading 0.8 lagging 0.351 lagging Unity D) unity None Hint Q59). The maximum regulation is: 1.5% 4% 5.5% 4.27% None Hint Q60). The power factor at which the regulation is zero is: 0.936 leading 0.936 lagging 0.8 leading 0.351 leading None Hint Q61). A transformer has R = 0.02 pu and X = 0.05 pu. At full load, 0.8 pf lagging, the regulation is: 3.6% 5.0% 7.0% 4.6% None Hint Before attempting transformer numerical problems, it is important to understand the basic concepts of transformers. You can strengthen your fundamentals by practising our 100+ Transformer MCQs with Answers, covering transformer principles, types, construction, testing, applications and other important theoretical concepts. None Q62). The percentage resistance and reactance drops ε_r and ε_x are: 1.25% and 3% 2.5% and 6% 0.5% and 1.2% 1.25% and 6%) 1.25% None Hint Q63). The full-load regulation at 0.8 pf lagging is: 4.25% 3.6% 2.8% 1.8% None Hint Q64). The secondary terminal voltage at full load, 0.8 pf lagging, with 2000 V applied, is: 196.4 V 194.4 V 188 V 200 V None Hint Q65). A transformer has a full-load regulation of 3.6% at 0.8 pf lagging. At half load (same pf), the regulation is approximately: 1.8% 3.6% 0.9% 7.2% None Hint Q66). A transformer has a 5% regulation (referred to the no-load voltage) and a no-load secondary voltage of 400 V. The loaded secondary voltage is: 375 V 380 V 395 V 420 V None Hint Q67). A transformer has a per-unit impedance of 5%. The steady-state short-circuit current, with rated voltage applied, is how many times the rated current? 5 10 20 50 None Hint Q68). A 1000 kVA, 11 kV/433 V, 3-phase transformer has 5% impedance. The short-circuit current on the LV side, with rated voltage on the HV side, is about: 1.33 kA 13.3 kA 53.3 kA 26.7 kA None Hint Q69). A transformer has ε_r = 2% and ε_x = 6%. At 0.6 pf lagging the regulation is: 4.8% 7.2% 6.0% x 8.0% None Hint Q70). A transformer supplies a load with a leading power factor lower than its zero-regulation power factor (that is, a more capacitive load). The secondary terminal voltage: falls below its no-load value stays unchanged becomes zero rises above its no-load value None Hint Q71). Which of the following is NOT required for two transformers to operate in parallel with proportional load sharing The same polarity Equal kVA ratings The same voltage ratio Equal per-unit impedances None Hint Q72). Two transformers of 100 kVA and 200 kVA have equal percentage impedance. They supply a total load of 240 kVA. The shares are: 80 and 160 kVA 120 and 120 kVA 100 and 140 kVA 60 and 180 kVA None Hint Q73). The load on T1 is: 100 kVA 115.4 kVA 120 kVA 184.6 kVA None Hint Q74). The load on T2 is: 184.6 kVA 200 kVA 180 kVA 115.4 kVA None Hint Q75). Which transformer is overloaded in this case? T2, as it has the higher impedance Both transformers Neither transformer T1, as it has the lower impedance None Hint Transformer Calculations MCQs for Quiz Q76). The maximum total load that can be supplied without overloading either transformer is: 300 kVA 240 kVA 260 kVA 280 kVA None Hint Q77). A 500 kVA, 5% transformer is paralleled with a 250 kVA, 4% transformer. The maximum load without overloading either is: 750 kVA 700 kVA 600 kVA 650 kVA None Hint Q78). A 100 kVA, 4% transformer is in parallel with a 150 kVA, 3% transformer. The maximum total load is: 250 kVA 200 kVA 225 kVA 240 kVA None Hint Q79). For the same pair as Q78, with a total load of 200 kVA, the 150 kVA transformer carries: 133.3 kVA 100 kVA 150 kVA 66.7 kVA None Hint Q80). Two 400 kVA transformers have impedances of 5% and 6%. They supply 600 kVA. The first (5%) carries: 300 kVA 327.3 kVA 350 kVA 272.7 kVA None Hint Q81). If two transformers in parallel have different voltage ratios, then: A circulating current flows even with no load Circulating current flows only at full load Load sharing is unaffected The iron loss falls to zero None Hint Q82). Two transformers in parallel have secondary EMFs differing by 2 V. The sum of their impedances referred to the secondary is 0.2 Ω. The no-load circulating current is: 20 A 5 A 0.1 A 10 A None Hint Q83). Two transformers of equal kVA rating, each with 4% impedance, have voltage ratios that differ by 1%. The circulating current as a percentage of rated current is: 25% 12.5% 6.25% 1% None Hint Q84). Two transformers have equivalent impedances of |Z1| = 0.5 Ω and |Z2| = 1.0 Ω with the same impedance angle. The total load current is 300 A. The current in the first transformer is: 100 A 150 A 200 A 250 A None Hint Q85). Two transformers of 300 kVA and 700 kVA have equal per-unit impedance. The total load is 600 kVA. The 700 kVA unit carries: 300 kVA 360 kVA 420 kVA 450 kVA None Hint Q86). Two 500 kVA transformers have impedances of 2% and 4%. The total load is 600 kVA. The load on the 4% transformer is: 300 kVA 200 kVA 250 kVA 400 kVA None Hint Q87). A Dyn11 transformer and a Dyn1 transformer of the same ratings: Can be paralleled when their kVA ratings match Can be paralleled using tap changers Can be paralleled without any change Cannot be paralleled, as the groups differ by 60° None Hint Q88). Yy0 and Dd0 transformers of equal ratio and impedance: Can be paralleled, as both groups have zero phase shift Cannot be paralleled, as one is star and the other delta Can be paralleled only after changing taps Cannot be paralleled, as their kVA ratings differ None Hint Q89). Connecting transformers in parallel with the wrong phase sequence causes: A small circulating current A short circuit between phases No effect A lower iron loss None Hint Q90). If paralleled transformers have different X/R ratios, then: The combined efficiency rises The regulation becomes zero The unit currents are out of phase, reducing total capacity There is no effect on sharing None Hint 91). As a rule of thumb, paralleling transformers whose kVA ratings differ by more than about 3:1 is generally avoided because: Their X/R ratios usually differ widely Their costs differ greatly Their cooling cannot be matched Their noise levels add up None Hint Q92). A 200 kVA transformer has 2.5% impedance. On a 100 kVA base, with the voltage base unchanged, its per-unit impedance is: 2.5% 5% 0.625% 1.25% None Hint Q93). A transformer has X1 = 5 Ω, X2 = 0.03 Ω and K = N2/N1 = 0.1. The equivalent reactance referred to the primary, X01, is: 5.03 Ω 3.03 Ω 5 Ω 8 Ω None Hint Q94). A 1000 kVA transformer with 6% impedance is supplied from an infinite bus. The fault level on its secondary side is: 16.67 MVA 6 MVA 60 MVA 1.67 MVA None Hint Q95). A 500 kVA transformer has 5% impedance. On a 1000 kVA base, with the voltage base unchanged, it is: 2.5% 10% 5% 20% None Hint Q96). A 440 V/220 V autotransformer delivers 10 kVA to the load. The power transferred by transformer action (not by direct conduction) is: 10 kVA 2.5 kVA 5 kVA 7.5 kVA None Hint Q97). Compared with a two-winding transformer of the same output, the saving in copper for an autotransformer with k = 0.5 is about: 50% 25% 75% None None Hint Q98). The Sumpner (back-to-back) test on two identical transformers is used to determine: The turns ratio and polarity of the windings Iron loss, copper loss and temperature rise under load The winding resistance at ambient temperature The insulation resistance and breakdown voltage None Hint Q99). A 3-phase, 500 kVA, 11 kV/415 V transformer has an LV line current of: 347.8 A 1205 A 695.6 A 1500 A None Hint Q100). The cooling designation ONAN stands for: Oil Normal, Air Normal Oil Naturally Aged, Natural Oil Neutral, Air Neutral Oil Natural, Air Natural None Hint Working through these 100 questions should have made a few patterns clear. Losses decide almost everything else. Iron loss is fixed by voltage and frequency, copper loss grows with the square of the load, and the efficiency, the ideal operating point and the heating all follow from those two facts. Efficiency peaks where the two losses are equal. This is why distribution transformers, which are always energised but often lightly loaded, are designed differently from those that run near full load.Regulation depends on power factor as much as on load. Lagging loads make the terminal voltage fall. Sufficiently leading loads can make it rise. Between them lies a power factor at which regulation is zero. In parallel operation, per-unit impedance matters more than kVA rating. A transformer with lower per-unit impedance takes more than its share of the load and reaches its limit first. That can leave the pair unable to supply the sum of their ratings.If you got a question wrong, redo it from its hint before moving on. A mistake in a hint or a worked answer is also worth checking against your textbook. Doing this a few times usually makes the formulas automatic, and that is the real goal of any practice set. Time's up